A North Sea operator sought a solution to reduce underreaming vibrations
The Expro HI TOOL® Harmonic Isolation Tool was deployed in the 8 1/2” - 9 1/2” sidetrack to mitigate vibration harmonics traveling from the underreamer assembly downward into the M/LWD RSS BHA. The objective was to drill the sidetrack in one run
Expro Excellence
It was suspected that the vibrations were caused by vibration harmonics created by the underreamer traveling down and could accelerate toward the lower BHA. The HI TOOL® Harmonic Isolation Tool was placed just above the M/LWD-RSS BHA to decouple the underreamer interference and prevent vibrations traveling into the costly BHA
Value to Client
In this well, with the HI TOOL® Harmonic Isolation Tool above the M/ LWD-RSS BHA and below the underreamer, both axial and lateral vibrations were greatly minimized. The section was drilled in two runs with an improvement of 44% ROP when compared to the offset wellThe PDC Bit graded 1-1-CT-N-X-I-NO-TD
Reduction of axial and lateral vibrations
Smooth drilling throughout section
Protects M/LWD-RSS BHA from underreamer harmonics and vibrations