Case Study

Improving Flow Assurance with Gas Tracer Monitoring

Customer Challenges

  • The operator required independent verification of gas flow measurement on a 48-inch flare line, as the readings from the permanently installed thermal meter were not considered sufficiently reliable 
  • Accurate flare gas measurement was essential for operational monitoring, flare reporting, emissions estimation, and measurement assurance 
  • The flare system experienced low, unstable and highly transient flow conditions, with gas entering the flare header from multiple upstream sources including separator outlets and relief systems 
  • Due to the large pipe size and the requirement to avoid shutdown or piping modifications, Gas Tracing was selected as the most suitable temporary verification technique

Expro Excellence

  • Expro deployed its Gas Tracing solution using existing injection and sampling ports, eliminating the need for any permanent modifications to the pipeline 
  • A known quantity of tracer gas was injected into the flare line and sampled approximately 25 metres downstream after complete mixing
  • The total gas flow rate was calculated using the tracer dilution (mass balance) principle, providing a representative measurement of the entire pipeline flow 
  • The measured flow rates were independently compared with the permanently installed thermal meter throughout two monitoring campaigns

Value to Client

  • Provided an independent reference measurement to assess the performance of the installed thermal meter 
  • Demonstrated that the installed thermal meter was considerably over-reading as compared with the Gas Tracing measurements under the observed operating conditions 
  • Enabled evidence-based assessment of flare measurement performance without interrupting production 
  • Eliminated the need for costly pipeline modifications or installation of an inline flow meter 
  • Improved confidence in flare gas reporting, emissions estimation and operational decision-making 
  • Delivered a temporary, portable and minimal intrusive verification solution using existing pipeline connections