A Geothermal customer noticed increased iron counts from one of their producing wells, the well also had a known scale build up issue
They had older fields with corrosion issues and wanted to be proactive with this issue in order to assure the future production
The wells were completed with 9 5/8” casing and 7” perforated or slotted liner below
The scope was to run a Multi- Finger Caliper to log the entire wellbore, including the liner and casing
The downhole temperature was 640°F
Expro Excellence
Expro is the market leader for the provision of Geothermal Multi-Finger Calipers and associated expertise
The Expro solution meant the customer did not have to “quench” the well in order to log it
The Kinley Multi-Finger Caliper and subsequent analysis successfully provided a “snapshot” of the condition of the wellbore, costing the client only hours of shut-in time to log the well
Expro provided the Caliper and technician and partnered with a local conveyance company to expedite logistics and minimize costs
Value to Client
The customer was able to identify casing degradation before it became a serious production issue
The Kinley Caliper was the most operationally efficient way for the customer to proactively identify the corrosion and extent of the scale buid-up
The customer was then able to implement a solution to remediate the scale build-up and maintain production