Expro was approached by Centrica to review a leakage in the casing cement with formation fluid that had entered the annulus and created a salt plug
During a routine bleed-off the annulus pressure dropped to 0 Psi, which illustrated that the annulus was blocked. This would have resulted in the well being shut in because of these integrity issues
The customer was unable to bleed of the pressure built-up in the annulus and the consequences could have led to the casing collapsing
Expro Excellence
Expro offered a bespoke solution to run Octopoda® - our annulus intervention system in the salt plug, displacing the annulus from the Zechstein formation fluid, replacing it with fresh water which would dissolve the salt plug
Expro’s annulus intervention system offers minimally intrusive equipment allowing the remediation of annular integrity issues without the use of a heavy workover rig. The alternative for the customer would have been using a workover rig and without this solution there was a high possibility that the casing would have collapsed
Our Octopoda® - annulus intervention system allowed us to enter through the casing hanger and run down the annulus
Our system displaced the annulus fluid while removing and measuring salt content. This operation was completed in four runs
Communicating pressure to the reservoir was achieved after circulating fresh water on depth
After circulating fresh water in the reservoir the annulus pressure was successfully restored
Value to Client
Expro is the only provider of this annular intervention service
Without the requirement for a workover rig this significantly reduced the customers cost
A bespoke solution was made for Centrica for this job and full scale testing was performed at our Expro base before mobilising offshore
Increased oil recovery through the revitalisation of a well which would have been previously shut-in