The customer was experiencing issues with a geothermal well, suspecting a casing integrity issue. The well was subsequently taken off line
The customer needed to evaluate the condition of the well, remediate any issues and bring the well back on line
Key objectives were to evaluate any integrity issues, including the requirement identify any external forces on the well that could cause the suspected integrity issue
Expro Excellence
Expro was sourced provide a fully integrated well integrity evaluation and remediation solution
Expro ran a suite well integrity evaluation tools including a Multi-Finger Caliper (MFC), Cement Bond Log (CBL) a Magnetic Thickness Detector (MTD) and a Spectral Noise Logging (SNL) tool
The MFC enabled evaluation of the 13 3/8” casing geometry, with multiple anomalies identified
With a bridge plug was set to isolate the section below the 10 3/4” liner hanger, the CBL was run into the well under quenched conditions to map the cement integrity behind the 13 3/8” casing
The SNL tool was run to evaluate the source and path of any leaks. A leak along with its path was identified behind the casing between ~ 510m and ~590m
The MTD tool was run to compliment the data gathered from the CBL, SNL and MFC
Following the data evaluation and job planning phase, Expro executed the remediation phase by running a series of cement squeeze
A CBL was run post cement squeeze to verify the quality of the cement job
Value to Client
The customers casing integrity issue was successfully remediated
By sourcing a fully integrated solution from Expro, this enabled the delivery of a safe and efficient outcome, with the well being brought back on line within budget